Detail Fluke 1587 Insulation Multimeter

Fluke 1587 Insulation Multimeter From the Manufacturer The Fluke 1587 insulation multimeter combines a digital 1 Kv insulation tester and full featured true-rms digital multimeter in a single compact handheld unit. It provides maximum versatility for both troubleshooting and preventive maintenance. Like other tools from Fluke, the 1587 is rugged, reliable and easy to use. Whether you work on motors, generators, cables, or switch gear, this Insulation Multimeter is ideally suited to help you with your task. It includes a remote probe, test leads, alligator clips, K-type thermocouple, four AA alkaline batteries, quick reference guide, CD Rom with manual all included in a hard case, that allows you to bring everything you need for the job. Product Features Insulation test voltages 50 volts; 100 volts; 250 volts; 500 volts; 1, 000 volts Live circuit detection prevents insulation test if voltage of more than 30 volts is detected Auto-discharge of capacitive voltage for added user protection AC/ DC voltage, DC milliVolts, AC/ DC milliamps, resistance, continuity Testing for capacitance, diode, temperature, min/ max, and frequency Spesifikasi - Fluke 1587 Insulation Multimeter Specifications Voltage DC Maximum Voltage: 1000 V Accuracy: 1577: ± ( 0.2% + 2) 1587: ± ( 0.09% + 2) Maximum Resolution: 0.001V Voltage AC Maximum Voltage: 1000 V Accuracy: 1577: ± ( 2% + 3) 1587: ± ( 2% + 3) AC Bandwidth: 1587: 5kHz* * with low pass filter; 3db @ 800 Hz Maximum Resolution: 0.1 mV Current DC Maximum Amps: 400mA Amps Accuracy: 1577: ± ( 1.0% + 2) 1587: ± ( 0.2% + 2) Maximum Resolution: 0.01 mA Current AC Maximum Amps: 400mA Amps Accuracy: 1577: ± ( 2.0% + 2) * 1587: ± ( 1.5% + 2) * * 1kHz bandwidth Maximum Resolution: 0.01 mA Resistance Maximum Resistance: 50 M© Accuracy: 1577: ± ( 1.2% + 2) 1587: ± ( 0.9% + 2) Maximum Resolution: 0.1© Capacitance( 1587 only) Maximum Capacitance: 9, 999 µ F Accuracy: ± ( 1.2% + 2) Maximum Resolution: 1 nF Frequency ( 1587 only) Maximum Frequency: 100 kHz Accuracy: ± ( 0.1% + 1) Maximum Resolution: 0.01 Hz Temperature Measurement ( 1587 only) -40.0 ° C to 537 ° C -40.0 ° F to 998 ° F excluding probe Diode Test ( 1587 only) Range: 6 V Resolution: 1 mV Accuracy: ± ( 2 % + 1) Insulation Test Minimum Test Current @ 1k© / V: 1mA Test Voltages: 1577: 500, 1000 V 1587: 50, 100, 250, 500, 1000 V Maximum Resistance per Test Voltage: 50V: 100V: 250V: 500V: 1000V: 1577: 600 M© 1587: 2 G© Maximum Resolution per Test Voltage: 50V: 0.01 M© 100V: 0.01 M© 250V: 0.1 M© 500V: 0.1 M© 1000V: 0.1 M© Accuracy per Test Voltage: 50V: ± ( 3 % + 5) 100V: ± ( 3 % + 5) 250V: ± ( 1.5 % + 5) 500V: 1577: ± ( 2.0 % + 5) 1587: ± ( 1.5 % + 5) 1000V: 1577: ± ( 2.0 % + 5) 1587: ± ( 1.5 % + 5) to 600 M© , ± ( 10 % + 3) above 600 M© Environmental Specifications Operating temperature – 20 ° C to + 55 ° C Storage temperature -40° C to + 60° C Humidity ( Without Condensation) 0% - 95% ( 10 ° C – 30 ° C) 0% - 75% ( 30 ° C – 40 ° C) 0% - 40% ( 40 ° C – 55 ° C) Operating Altitude 2000 m Safety Specifications Overvoltage category Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V Agency Approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V Mechanical & General Specifications Size 203 x 100 x 50 mm ( with holster) Weight 624 g Warranty 3 years Battery life Alkaline Meter use: 1000 hours Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off. IP Rating IP40
Tampilkan Lebih Banyak