Detail Fluke 1587 Insulation Multimeter
Fluke 1587 Insulation Multimeter
From the Manufacturer
The Fluke 1587 insulation multimeter combines a digital 1 Kv insulation tester and full featured true-rms digital multimeter in a single compact handheld unit. It provides maximum versatility for both troubleshooting and preventive maintenance. Like other tools from Fluke, the 1587 is rugged, reliable and easy to use. Whether you work on motors, generators, cables, or switch gear, this Insulation Multimeter is ideally suited to help you with your task. It includes a remote probe, test leads, alligator clips, K-type thermocouple, four AA alkaline batteries, quick reference guide, CD Rom with manual all included in a hard case, that allows you to bring everything you need for the job.
Product Features
Insulation test voltages 50 volts; 100 volts; 250 volts; 500 volts; 1, 000 volts
Live circuit detection prevents insulation test if voltage of more than 30 volts is detected
Auto-discharge of capacitive voltage for added user protection
AC/ DC voltage, DC milliVolts, AC/ DC milliamps, resistance, continuity
Testing for capacitance, diode, temperature, min/ max, and frequency
Spesifikasi - Fluke 1587 Insulation Multimeter
Specifications
Voltage DC
Maximum Voltage: 1000 V
Accuracy: 1577: ± ( 0.2% + 2)
1587: ± ( 0.09% + 2)
Maximum Resolution: 0.001V
Voltage AC
Maximum Voltage: 1000 V
Accuracy: 1577: ± ( 2% + 3)
1587: ± ( 2% + 3)
AC Bandwidth: 1587: 5kHz*
* with low pass filter; 3db @ 800 Hz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 400mA
Amps Accuracy: 1577: ± ( 1.0% + 2)
1587: ± ( 0.2% + 2)
Maximum Resolution: 0.01 mA
Current AC
Maximum Amps: 400mA
Amps Accuracy: 1577: ± ( 2.0% + 2) *
1587: ± ( 1.5% + 2) *
* 1kHz bandwidth
Maximum Resolution: 0.01 mA
Resistance
Maximum Resistance: 50 M©
Accuracy: 1577: ± ( 1.2% + 2)
1587: ± ( 0.9% + 2)
Maximum Resolution: 0.1©
Capacitance( 1587 only)
Maximum Capacitance: 9, 999 µ F
Accuracy: ± ( 1.2% + 2)
Maximum Resolution: 1 nF
Frequency ( 1587 only)
Maximum Frequency: 100 kHz
Accuracy: ± ( 0.1% + 1)
Maximum Resolution: 0.01 Hz
Temperature Measurement ( 1587 only)
-40.0 ° C to 537 ° C
-40.0 ° F to 998 ° F
excluding probe
Diode Test ( 1587 only)
Range: 6 V
Resolution: 1 mV
Accuracy: ± ( 2 % + 1)
Insulation Test
Minimum Test Current @ 1k© / V:
1mA
Test Voltages:
1577: 500, 1000 V
1587: 50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage:
50V:
100V:
250V:
500V:
1000V: 1577: 600 M©
1587: 2 G©
Maximum Resolution per Test Voltage:
50V: 0.01 M©
100V: 0.01 M©
250V: 0.1 M©
500V: 0.1 M©
1000V: 0.1 M©
Accuracy per Test Voltage:
50V: ± ( 3 % + 5)
100V: ± ( 3 % + 5)
250V: ± ( 1.5 % + 5)
500V: 1577: ± ( 2.0 % + 5)
1587: ± ( 1.5 % + 5)
1000V: 1577: ± ( 2.0 % + 5)
1587: ± ( 1.5 % + 5) to 600 M© , ± ( 10 % + 3) above 600 M©
Environmental Specifications
Operating temperature
– 20 ° C to + 55 ° C
Storage temperature
-40° C to + 60° C
Humidity ( Without Condensation)
0% - 95% ( 10 ° C – 30 ° C)
0% - 75% ( 30 ° C – 40 ° C)
0% - 40% ( 40 ° C – 55 ° C)
Operating Altitude
2000 m
Safety Specifications
Overvoltage category
Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications
Size
203 x 100 x 50 mm ( with holster)
Weight
624 g
Warranty
3 years
Battery life Alkaline
Meter use: 1000 hours
Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating
IP40
Tampilkan Lebih Banyak